Accessibility – how to mount and de-mount Ecophon ceiling systems
Ecophon offers ceiling systems with full demountability, even with concealed suspension systems.
Ceilings with a large amount of integrations require careful planning, design and installation. The table below indicates minimum depth for demountability and minimum depth of system applicable to each ceiling system.
Δ = |
Minimum overall depth of system: the dimension from the underside of the structural soffit to the underside of the suspended ceiling |
|
δ = |
Minimum depth for demountability: the dimension required to fit and demount individual ceiling panels. It is measured from the underside of the suspended ceiling. |
The Δ o.d.s.is measured, while the figures for the required δ m.d.d. are empirically assessed. In practical terms, this means that the measurements might vary slightly depending on the skill and experience of the installer.
Accessibility and demountability for Ecophon ceiling systems
Ceiling system | Minimum overall depth of system Δ (mm) | Minimum depth for demountability δ (mm) |
Access A | 120 | 80 |
Access C | 130 | 90 |
Access Frieze | - | - |
Advantage A | 50-100 | 120-130 |
Advantage E | 60-110 | 90-110 |
Combison Duo A | 80-100 | 220 |
Combison Duo E | 90-110 | 230 |
Combison Uno A | 50-100 | 200 |
Combison Uno Ds | 105 | 40 |
Combison dB A | 100 | 210 |
Focus A | 50-100 | 120-130 |
Focus A XL | 40-100 | 65-100 |
Focus B | 23 | - |
Focus C | 23 | - |
Focus D/A | 50 | 75 |
Focus Dg | 65-115 | 30 |
Focus Dg XL & 1200x1200 | 65 | 30-55 |
Focus Ds | 65-105 | 30-40 |
Focus DS XL & 1200x1200 | 55-105 | 30-50 |
Focus E | 60-110 | 120-160 |
Focus E XL | 50-110 | 75-110 |
Focus Ez | 80-130 | 80 |
Focus F | 20 | - |
Focus Fixiform | - | - |
Focus Flexiform | - | - |
Focus Frieze | 110-160 | - |
Focus Lp | 105 | 20 |
Focus SQ | 23 | - |
Gedina A | 50-100 | 120-130 |
Gedina E | 60-110 | 120-130 |
Hygiene Advance A | 150 | 150-170 |
Hygiene Clinic A | 50-100 | 120 |
Hygiene Clinic E | 60-110 | 120-130 |
Hygiene Protec Ds | 105 | 30 |
Hygiene Protec Air A | 150 | 150-170 |
Hygiene Meditec A | 50-100 | 100-150 |
Hygiene Meditec E | 60-110 | 110-160 |
Hygiene Performance A | 150 | 150-170 |
Hygiene Performance Plus A | 150 | 150-170 |
Hygiene Performance Ds | 105 | 30 |
Hygiene Protec A | 150 | 150 |
Industry Ambit | 40 | - |
Industry Modus | 50-100 | 150-250 |
Industry RTP | 50-100 | 170-220 |
Master A | 50-100 | 170-200 |
Master B | 43 | - |
Master C | 43 | - |
Master Ds | 95-140 | 50 |
Master E | 60-110 | 170 |
Master F | 40 | - |
Master Matrix | 255 | 105-180 |
Master Rigid A | 100 | 120-150 |
Master Rigid Dp | 115 | 20 |
Master Rigid E | 110 | 120-170 |
Master SQ | 43 | - |
Solo | 90 | - |
Sombra A | 50-100 | 120 |
Super G A | 150-200 | 150-200 |
Super G B | 43 | - |
Super G Plus A | 42-305 | - |