System range
Size, mm
600x600
Direct
Thickness 40
Inst. Diagr. M298
System and product description
For applications where the minimum possible overall depth of system is required and where there is risk of high mechanical impact. The tiles are bonded edge-to-edge directly to the soffit surface, creating a ceiling with a smooth appearance. The bevelled edges create a narrow groove between each tile. The tiles are not demountable.

The tiles are manufactured from high density glass wool utilizing the 3RD Technology. The visible surface is a strong glass fibre fabric and the back of the tile is covered with glass tissue. The edges are painted. The weight is approximately 5 kg/m².

Ecophon recommend Connect Absorber Glue for a quick and easy installation.
Acoustics
Acoustic:
αp Practical sound absorption coefficient
Super G_B_abs1 Frequency Hz
···· Ecophon Super G B 43 mm o.d.s.
o.d.s = overall depth of system
Sound Absorption: Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
Sound Insulation: Not applicable
Sound Privacy: Not applicable
Product SuperG B
o.d.s mm 43
absorption class A
αw 1,0
NRC 0,9
SAA 0,9
Technical properties
Accessibility: The tiles are not demountable.
Cleanability: Daily dusting and vacuum cleaning. Weekly wet wiping.
Visual appearance: White 085. Nearest NCS colour sample: S 1002-Y. Light reflectance: 78%.
Influence of climate: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate: Certified by the Indoor Climate Labelling, emission class M1 for building materials and recommended by the Swedish Asthma and Allergy Association.
Environmental influence: Glass wool core utilizing 3RD Technology. Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety: The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003.
Country Standard Class
Europe EN 13501-1 A2-s1,d0
Mechanical properties: M298 is tested and classified as 3A according to EN 13964 annex D. Additional live load has to be fixed to the soffit.
Max live load (N) Min load bearing capacity (N)
M298, 600x600 - -
Installation: Installed according to installation diagrams, installation guides and drawing aid. For information regarding minimum overall depth of system see quantity specification. Rendered surfaces must have sufficient strength to be able to carry the load imposed by the tiles. If doubts, test gluing should be carried out. The surface should always be dry and clean. For best result the surface should be even. Install tiles according to arrows.