Master
Master™ F
System range
Size, mm
600x600 1200x600
Direct
Thickness 40 40
M52 M52
System and product description
uitable for schools, open plan offices or other premises where strict demands are made on good acoustics and speech intelligibility. Ecophon Master F is installed directly to an existing plaster ceiling, boarding, battens or concrete, creating a ceiling with a smooth appearance. The bevelled edges create a narrow groove between each tile. The tiles are not demountable.

The tiles are manufactured from high density glass wool. The visible surface has an Akutex FT coating and the back of the tile is covered with glass tissue. The edges are reinforced and painted. The weight is approximately 5 kg/m².

Ecophon recommend Connect screws for a quick and secure installation.
Acoustics
Acoustic:
αp Practical sound absorption coefficient
Master_F_abs1 Frequency Hz
— Ecophon Master F/alpha 40 mm o.d.s.
···· Ecophon Master F/beta 40 mm o.d.s.
--- Ecophon Master F/gamma 40 mm o.d.s.
o.d.s = overall depth of system
Sound Absorption: Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
Sound Insulation: Not applicable.
Sound Privacy: Not applicable
Product Master F
o.d.s mm 40 60
absorption class A A
NRC 0,95 -
SAA 0,95 -
αw
Technical properties
Accessibility: The tiles are not demountable.
Cleanability: Daily dusting and vacuum cleaning. Weekly wet wiping.
Visual appearance: White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection). Retro reflection coefficient 63 mcd/(m²lx). Gloss < 1.
Influence of climate: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate: Certified by the Indoor Climate Labelling, recommended by the Swedish Asthma and Allergy Association, and can be used in rooms classified as ISO class 6 according to ISO 14644-1.
Environmental influence: Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety: The glass wool core of the tiles is tested and classified as non-combustible according to prEN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003. See Technical properties, Fire safety.
Country Standard Class
Europe EN 13501-1 A2-s1,d0
Mechanical properties: Additional live load has to be secured to the soffit.
Max live load (N) Min load bearing capacity (N)
M52, 600x600 - -
M52, 1200x600 - -
Installation: Installed according to system range which includes information regarding minimum overall depth of system.
It is not always possible to install a traditional suspended acoustic ceiling, yet the sound environment has to be improved for the people using the room. Direct mounting by screw or glue could be the quick and easy answer.