System and product description
Ecophon Hygiene Advance A C3 system is a wall to wall, sound-absorbing ceiling system intended for use in environments where there is a high level of contamination, and where frequent cleaning is required. The system is also an excellent choice for clean environments with high demands on low particle emissions. Examples of applications: areas with high levels of airborne grease, areas exposed to splatter from meat juices, fruit juices or other liquids and environments with extremely high requirements on particle emissions.
The system consists of Ecophon Hygiene Advance A tiles, which have a core of high density glass wool encapsulated in a smooth high-performance film that is impervious to particles and water. The film is also dirt-repellent and resistant to most chemicals. The supporting structure is a corrosion protected exposed Connect T24 C3 grid of lacquered galvanised steel. The weight of the system is 3-4 kg/m². The tiles should be secured to the grid with Connect Hygiene clips in order to withstand pressure during cleaning and to minimise dirt traps.
M252
M252
VIEW 3D
Download installation guide
IG
-104 Connect Inspection hatch C3
(201.75 kB)
Drawing Aid
Transitions
Installations
Fixings
Search
See Quantity specification
Arrangement of clips
Clips for keeping tiles in place
Clip for keeping tiles in place for 20 mm tiles
Quantity specification (excl. wastage)
Installation diagram (M252) for Ecophon Hygiene Advance A C3
Size, mm
600x600
1200x600
1 Hygiene Advance A
2,8/m²
1,4/m²
2 Connect T24 Main runner C3, installed at 1200 mm centres
0,9m/m²
0,9m/m²
3 Connect T24 Cross tee C3, L=1200 mm, installed at 600 mm centres
1,7m/m²
1,7m/m²
4 Connect T24 Cross tee C3, L=600 mm
0,9m/m²
-
5 Connect Adjustable hanger C3, c1200 (max distance from wall 600 mm)
0,7/m²
0,7/m²
6 Connect Hanger clip
0,7/m²
0,7/m²
7 Connect Inspection hatch C3
as required
as required
8 Connect Hygiene clip 20
11/m²
7/m²
9 Connect Hygiene clip 40
11/m²
7/m²
10 Connect Channel trim C3, fixed c300 (for 20 mm thickness)
as required
as required
11 Connect Channel trim C3, fixed c300 (for 40 mm thickness)
as required
as required
12 Connect Hygiene Advance Tape
as required
as required
13 Joint sealant (not supplied by Ecophon)
as required
as required
14 Ecophon Hygiene Advance technical tile (thickness 20 mm)
as required
as required
Δ Min. overall depth of system: 150 mm
-
-
δ Min. demounting depth 20 mm: 150 mm
-
-
δ Min. demounting depth 40 mm: 170 mm
-
-
Acoustics
Acoustic:
α
p
Practical sound absorption coefficient
Frequency, Hz
—
Ecophon Hygiene Advance A C3, 20mm, 200 mm o.d.s.
····
Ecophon Hygiene Advance A C3, 40mm, 200 mm o.d.s.
o.d.s= overall depth of system
Sound Absorption:
Test results according to EN ISO 354.
Classification according to EN ISO 11654.
Sound Insulation:
Not applicable.
Sound Privacy:
Not applicable
Product
Hygiene Advance A C3, 20 mm thick
Hygiene Advance A C3, 40 mm thick
o.d.s mm
200
200
absorption class
B
A
NRC
0,80
0,75
SAA
0,76
0,76
αw
Technical properties
Accessibility:
The tiles are demountable. Minimum demounting depth according to installation diagram. The tiles are secured using clips to allow for effective cleaning. The clips are easily removable from above the ceiling. An easy-to-open Connect Inspection hatch is available to simplify access to the ceiling void.
Cleanability:
Daily dusting, vacuum cleaning, manual wet cleaning, high-pressure washing and steam cleaning. Water temperature max. 70°C. Can withstand the use of common disinfecting chemicals.
Visual appearance:
White 141, nearest NCS colour sample S 1000-N, 73% light reflectance. Please note: There is a small difference in gloss between the Hygiene Advance tile and the Hygiene Advance perimeter tile.
Influence of climate:
The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611). A higher temperature/moisture is permissible during washing as stated above. The grid and accessories meet the demands of corrosion class C3 according to EN ISO 12944-2. For the microbiological resistance see Functional demands, Influence of climate.
Indoor Climate:
Can be used in rooms classified as ISO class 3 according to ISO 14644-1.
Fire safety:
The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. See Functional demands, Fire safety.
Country
Standard
Class
Europe
EN 13501-1
A2-s1,d0
Mechanical properties:
For information regarding live load and requirements for load bearing capacity, see installation diagrams. Conditions: See Functional demands, Mechanical properties.
Max live load (N)
Min load bearing capacity (N)
M252
, 600x600
40
160
M252
, 1200x600
40
160
Installation:
Installed according to system range. Cut tiles must be sealed with Connect Hygiene Advance Tape. Penetrations must be sealed with a suitable sealant.
Contact Us
We help you with technical solutions and answers to your questions about our products.
Read more
Hygiene Premises overview
Hygiene system overview & Quickguide - Room types
Download
Hygiene system brochure.pdf
3D CAD
A new feature turns watching installation diagrams into a 3D experience! Add another dimension to watching our installation diagrams. With our latest innovation we let you twist and turn and view close-ups directly on your computer.
Read more
Copyright © 2002-2012 Ecophon Group. All rights reserved.
Trademarks
Cookies
Disclaimer
Tell a friend
Close
Your friends name:
*
Your friends email:
*
Your name:
*
Your e-mail:
*
Your message:
Transitions
Installation
Fixing
Search
Subcategory
Detail list
Previous image
Next image
Type
Name
Description
Product
Sketch
Result
Previous image
Next image
Close