Focus
Focus™ SQ
System range
Size, mm
600x600 1200x600
Direct
Thickness 20 20
Inst. Diagr. M107 M107
System and product description
For applications where the minimum possible overall depth of system is required because of limited space or other reasons. The tiles are bonded directly to the soffit surface. Ecophon Focus SQ is installed with a gap between each tile, creating a ceiling with a smooth appearance. The tiles are not demountable.

The tiles are manufactured from high density glass wool utilizing the 3RD Technology. The visible surface has an Akutex™ FT coating and the back of the tile is covered with glass tissue. The edges are painted. The weight is approximately 2,5 kg/m².

Ecophon recommend Connect Absorber Glue for a quick and easy installation.
Acoustics
Acoustic:
αp Practical sound absorption coefficient
Focus_SQ_abs1 Frequency Hz
···· Ecophon Focus SQ 23 mm o.d.s.
o.d.s = overall depth of system
Sound Absorption: Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
Sound Insulation: Not applicable
Sound Privacy: AC(1.5)=190 according to ASTM E 1111 and E 1110.
Product Focus SQ
o.d.s mm 23
absorption class C
αw 0,60
Technical properties
Accessibility: The tiles are not demountable.
Cleanability: Daily dusting and vacuum cleaning. Weekly wet wiping.
Visual appearance: White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection). Retro reflection coefficient 63 mcd/(m²lx). Gloss < 1.
Influence of climate: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate: Certified by the Indoor Climate Labelling, emission class M1 for building materials and recommended by the Swedish Asthma and Allergy Association.
Environmental influence: Glass wool core utilizing 3RD Technology. Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety: The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182.
Country Standard Class
Europe EN 13501-1 A2-s1,d0
Mechanical properties: Additional live load has to be fixed to the soffit.
Max live load (N) Min load bearing capacity (N)
M107, 600x600 - -
M107, 1200x600 - -
Installation: Installed according to installation diagrams, installation guides and drawing aid. For information regarding minimum overall depth of system see quantity specification. Rendered surfaces must have sufficient strength to be able to carry the load imposed by the tiles. If doubts, test gluing should be carried out. The surface should always be dry and clean. For best result the surface should be even, however an acceptable result could be achieved on slightly uneven surfaces.