System range
Size, mm
XL
600x150
600x300
600x600
1200x150
1200x300
1200x600
1800x600
T24
•
•
•
•
•
•
•
Thickness
20
20
20
20
20
20
20
Inst. Diagr.
M279
M279
M278
M279
M279
M279
M278
M279
M278
System and product description
Ecophon Focus Lp has a semi-concealed grid system and is used for highlighting direction in a room. There is a wide gap between the tiles in the emphasized direction and narrow gap in the other. The edges are sharp and well defined. The system consists of standard Focus Lp tiles in 600 mm width and Focus Lp Technical tiles in widths of 150, 300 and 600 mm.
The tiles are manufactured from high density glass wool utilizing the 3RD Technology. The visible surface has an Akutex™ FT coating and the back of the tile is covered with glass tissue. The edges are painted. The Technical tiles are used to create areas for technical installations such as luminaires, ventilation, sprinklers, smoke detectors, loudspeakers etc. The exact width (148, 298 or 598 mm) is adopted to suit the standard sizes of luminaires on the market.
The tiles and Connect grid systems give an approximate weight of 3-4 kg/m2 for the system. The grid is manufactured from galvanized steel. For best performance and system quality, use Ecophon Connect grid and accessories.
M278
M279
M278
VIEW 3D
Download installation guide
IG278
-Focus Lp
(1.99 MB)
Drawing Aid
Transitions
Search
See Quantity specification
Distance between Focus Lp tiles
Demounting of tile
Non-supported edges meeting with space for cross-tee.
Quantity specification (excl. wastage)
Installation diagram (M278) for Ecophon Focus Lp
Size, mm
600x600
1200x600
1800x600
1 Focus Lp
2,8/m²
1,4/m²
0,95/m²
2 Connect T24 Main runner HD, installed at 600 mm centres
1,7m/m²
1,7m/m²
1,7m/m²
3 Connect T24 Cross tee, L=600 mm
2per row of Main runner
2per row of Main runner
2per row of Main runner
4 Connect Space bar 150, installed at 1500 mm centres (max. distance from wall 300 mm)
0,7m/m²
0,7m/m²
0,7m/m²
5 Connect Space bar winch, installed one per joint Main runner/Space bar
1,4/m²
1,4/m²
1,4/m²
6 Connect Wall bracket, L=700 mm, for Space bar
1 for every row of Space bar
1 for every row of Space bar
1 for every row of Space bar
7 Connect Wall bracket for T-profiles
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
8 Connect Absorber distance HD
5,6/m² (2/tile)
2,8/m² (2/tile)
1,9/m² (2/tile)
9 Connect Adjustable hanger, installed at 1200 mm centres (max. distance from wall 600 mm)
0,7/m²
0,7/m²
0,7/m²
10 Connect Hanger clip
0,7/m²
0,7/m²
0,7/m²
11 Connect Support clip Dg20
2per perimeter tile, cut on the long side
3per perimeter tile, cut on the long side
4per perimeter tile, cut on the long side
12 Connect Angle trim, fixed at 300 mm centres
as required
as required
as required
Δ Min. overall depth of system: 120 mm
-
-
-
δ Min. demounting depth: 20 mm
-
-
-
M279
VIEW 3D
Download installation guide
IG279
-Focus Lp Technical tile
(1.45 MB)
Drawing Aid
Transitions
Search
See Quantity specification
Distance between tiles overview
Distance between Focus Lp and Focus Lp Technical tile
Non-supported edges meeting with space for cross-tee.
Quantity specification (excl. wastage)
Installation diagram (M279) for Ecophon Focus Lp Technical tile
Size, mm
600x150
600x300
600x600
1200x150
1200x300
1200x600
1 Focus Lp Technical tile
11,1/m²
5,6/m²
2,8/m²
5,6/m²
2,8/m²
1,4/m²
2 Connect T24 Main runner HD
6,7m/m²
3,3m/m²
1,7m/m²
6,7m/m²
3,3m/m²
1,7m/m²
3 Connect T24 Cross tee, L=150/300/600 mm
as required
as required
as required
as required
as required
as required
4 Connect Space bar 150, installed at 1500 mm centres (max. distance from wall 300 mm)
0,7m/m²
0,7m/m²
0,7m/m²
0,7m/m²
0,7m/m²
0,7m/m²
5 Connect Space bar winch, installed one per joint Main runner/Space bar
8,9/m²
4,4/m²
2,2/m²
8,9/m²
4,4/m²
2,2/m²
6 Connect Wall bracket for T-profiles
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
7 Connect Absorber distance HD
22,2/m² (2/tile)
11,1/m² (2/tile)
5,6/m² (2/tile)
11,1/m² (2/tile)
5,6/m² (2/tile)
2,8/m² (2/tile)
8 Connect Adjustable hanger, installed at 1200 mm centres (max. distance from wall 600 mm)
5,6/m²
2,8/m²
1,4/m²
5,6/m²
2,8/m²
1,4/m²
9 Connect Hanger clip
5,6/m²
2,8/m²
1,4/m²
5,6/m²
2,8/m²
1,4/m²
10 Connect Angle trim, fixed at 300 mm centres
as required
as required
as required
as required
as required
as required
Δ Min. overall depth of system: 120 mm
-
-
-
-
-
-
δ Min. demounting depth: 20 mm
-
-
-
-
-
-
The area in quantity specification for M279 refers to the installation area between the two suspended Main runners. Maximum two rows of Technical tiles can be installed next to each other.
-
-
-
-
-
-
Acoustics
Acoustic:
α
p
Practical sound absorption coefficient
Frequency Hz
—
Ecophon Focus Lp 200 mm o.d.s.
o.d.s = overall depth of system
Sound Absorption:
Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
Sound Insulation:
Dn,f,w=24 dB according to ISO 140-9 and evaluation according to EN ISO 717-1. CAC=25 dB according to ASTM E 1414 and evaluation according to ASTM E 413.
Sound Privacy:
AC(1.5)=180 according to ASTM E 1111 and E 1110.
Product
Focus Lp
o.d.s mm
75
200
400
Class
A
A
αw
0,90
0,90
NRC
-
-
0,80
SAA
-
-
0,82
Technical properties
Accessibility:
The tiles are easily demountable. Minimum demounting depth according to installation diagrams.
Cleanability:
Daily dusting and vacuum cleaning. Weekly wet wiping.
Visual appearance:
White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection). Retro reflection coefficient 63 mcd/(m²lx). Gloss < 1.
Influence of climate:
The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate:
Certified by the Indoor Climate Labelling, emission class M1 for building materials and recommended by the Swedish Asthma and Allergy Association.
Environmental influence:
Glass wool core utilizing 3RD Technology. Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety:
The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003.
Country
Standard
Class
Europe
EN 13501-1
A2-s1,d0
Mechanical properties:
See table about Max live load and Min load bearing capacity and Functional demands, Mechanical properties at www.ecophon.com. For the Technical tiles installed according to M279 there is a load bearing capacity of 100 N for each Main runner HD per 1200 mm. This gives a total load bearing capacity of 200 N for a load evenly distributed on two Main runners.
Max live load (N)
Min load bearing capacity (N)
M278
, 600x600
50
160
M278
, 1200x600
50
160
M278
, 1800x600
50
160
M279
, 600x150
50
160
M279
, 600x300
50
160
M279
, 600x600
50
160
M279
, 1200x150
50
160
M279
, 1200x300
50
160
M279
, 1200x600
50
160
Installation:
Installed according to installation diagrams, installation guides and drawing aid. For information regarding minimum overall depth of system see quantity specification. The systems are not recommended for small rooms (approximately 2x2 m2). Ceilings with a large amount of integrations require careful planning, design and installation.
Contact us
We can help with technical solutions and answers to your questions about our products or room acoustics.
Read more
Connect Bridging
Connect Bridging is a simple solution for integration of lighting products, signs, smoke detectors etc. The weight of the installation will be transferred to the grid, and there will be no load on the tile.
Read more
Download
Ecophon Focus™ Lp - gives the ceiling direction.pdf
3D CAD
A new feature turns watching installation diagrams into a 3D experience! Add another dimension to watching our installation diagrams. With our latest innovation we let you twist and turn and view close-ups directly on your computer.
Read more
It's new, it's fresh - it's the new Acoustics
The new Acoustics features applied room acoustics for Office, Education and Healthcare premises. Here you can explore the individual segments, and by using the room selector you can read up on the specific needs and acoustic solutions for that particular room.
Read more
Copyright © 2002-2013 Ecophon Group. All rights reserved.
Trademarks
Cookies
Disclaimer
Tell a friend
Close
Your friends name:
*
Your friends email:
*
Your name:
*
Your e-mail:
*
Your message:
Transitions
Installation
Fixing
Search
Category
Subcategory
Detail list
Previous image
Next image
Type
Name
Description
Product
Sketch
Result
Previous image
Next image
Close