System and product description
Installation
Acoustics
Technical properties
System range
Size, mm
600x600
1200x600
Direct
•
•
Thickness
20
20
Inst. Diagr.
M15
M15
System and product description
For applications requiring a ceiling which is mechanically secured to the structural soffit. Ecophon Focus F is installed directly to an existing plaster ceiling, boarding, battens or concrete, creating a ceiling with a smooth appearance. The bevelled edges create a narrow groove between each tile. The tiles are not demountable.
The tiles are manufactured from high density glass wool utilizing the 3RD Technology. The visible surface has an Akutex™ FT coating and the back of the tile is covered with glass tissue. The edges are reinforced and painted. The weight is approximately 2,5 kg/m².
Ecophon recommend Connect screws for a quick and secure installation.
M15
M15
VIEW 3D
Download installation guide
IG15
-Focus F
(1.38 MB)
Drawing Aid
Transitions
Search
See Quantity specification
Installation in concrete
Installation in plasterboard or timber
Quantity specification (excl. wastage)
Installation diagram (M15) for Ecophon Focus F
Size, mm
600x600
1200x600
1 Focus F
2,8/m²
1,4/m²
2 Connect Direct fixing plate, installed at 600 mm centres (for use in concrete)
2,8/m²
2,8/m²
3 Connect Anchor screw, installed at 600 mm centres (for use in concrete)
2,8/m²
2,8/m²
4 Connect Installation screw MVL (for use in plasterboard or timber)
8,3/m²
7/m²
5 Connect Spline F, L=600 mm. Must be used in Sweden, Denmark, Norway and Finland at fireclass 'Tändskyddande beklädnad'
2,8/m²
1,4/m²
6 Connect Spline, L=150 mm
2,8/m²
1,4/m²
7 Connect Wall spring spacer
1per panel in the last row
2per panel in the last row
8 Connect Angle trim, fixed at 300 mm centres
as required
as required
9 For use when installing floating ceilings: Connect Wood trim, L=2500 mm, fixed at 500 mm centres
as required
as required
10 Timber installed at 600 mm centres (300 mm if thermal insulation is placed above), with the screw fixings along the timber.
as required
as required
Δ Min. overall depth of system: 20 mm
-
-
δ Min. demounting depth: The system is not demountable
-
-
Acoustics
Acoustic:
α
p
Practical sound absorption coefficient
Frequency Hz
····
Ecophon Focus F 20 mm o.d.s.
---
Ecophon Focus F 40 mm o.d.s.
—
Ecophon Focus F 430 mm o.d.s. including 385 mm thermal insulation.
o.d.s = overall depth of system
Sound Absorption:
Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
Sound Insulation:
Not applicable
Sound Privacy:
Not applicable
Product
Focus F
o.d.s mm
20
40
430
absorption class
C
C
A
αw
0,60
0,75
0,90
NRC
0,75
-
-
SAA
0,77
-
-
Technical properties
Accessibility:
The tiles are not demountable.
Cleanability:
Daily dusting and vacuum cleaning. Weekly wet wiping.
Visual appearance:
White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection). Retro reflection coefficient 63 mcd/(m²lx). Gloss < 1.
Influence of climate:
The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate:
Certified by the Indoor Climate Labelling, emission class M1 for building materials and recommended by the Swedish Asthma and Allergy Association.
Environmental influence:
Glass wool core utilizing 3RD Technology. Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety:
The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003.
Country
Standard
Class
Europe
EN 13501-1
A2-s1,d0
Mechanical properties:
Additional live load has to be fixed to the soffit.
Max live load (N)
Min load bearing capacity (N)
M15
, 600x600
-
-
M15
, 1200x600
-
-
Installation:
Installed according to installation diagrams, installation guides and drawing aid. For information regarding minimum overall depth of system see quantity specification. For best result the surface should be even, however an acceptable result could be achieved on slightly uneven surfaces. If very uneven surfaces – installation of furring (evenly spaced timber battens) as the substrate for the tiles is recommended.
Find out more - download the brochure
Quick and simple.pdf (7MB)
Read more
Direct fixing - the quick and simple solution
It is not always possible to install a traditional suspended acoustic ceiling, yet the sound environment has to be improved for the people using the room. Direct mounting by screw or glue could be the quick and easy answer.
Read more
Ecophon Wall Panel™
Our wall panel systems give you the opportunity to create an effective acoustic treatment of walls. Choose between our many inspiring colours and patterns.
Read more
Contact us
We can help with technical solutions and answers to your questions about our products or room acoustics.
Read more
Copyright © 2002-2013 Ecophon Group. All rights reserved.
Trademarks
Cookies
Disclaimer
Tell a friend
Close
Your friends name:
*
Your friends email:
*
Your name:
*
Your e-mail:
*
Your message:
Transitions
Installation
Fixing
Search
Category
Subcategory
Detail list
Previous image
Next image
Type
Name
Description
Product
Sketch
Result
Previous image
Next image
Close