Focus
Focus™ Ds
System range
Size, mm
XL XL XL XL
600x600 1200x600 1200x1200 1600x600 1800x600 2000x600 2400x600
T24
Thickness 20 20 20 20 20 20 20
Inst. Diagr. M206 M208 M206 M208 M207 M206 M208 M238 M206 M208 M238 M206 M208 M238 M206 M208 M238
System and product description
For applications where a suspended ceiling with a concealed grid is required, but individual tiles must be easily demountable. Ecophon Focus Ds has a concealed grid and symmetrical edge design, allowing easier assembly, integration of light fittings and ventilation. The ceiling has an even appearance, with the bevelled edges forming a discreet groove between the tiles. The tiles are easily demountable.

The systems consist of Ecophon Focus Ds tiles and Ecophon Connect grid systems, with an approximate weight of 3-4 kg/m². The tiles are manufactured from high density glass wool utilizing the 3RD Technology. The visible surface has an Akutex™ FT coating and the back of the tile is covered with glass tissue. The edges are painted. For best performance and system quality, use Ecophon Connect grid and accessories. The grid is manufactured from galvanized steel. The system is patented.
Acoustics
Acoustic:
αp Practical sound absorption coefficient
Focus_Ds_abs1 Frequency Hz
Ecophon Focus Ds 200 mm o.d.s.
···· Ecophon Focus Ds 60 mm o.d.s.
o.d.s = overall depth of system
Sound Absorption: Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
Sound Insulation: Dn,f,w=24 dB according to ISO 140-9 and evaluation according to EN ISO 717-1. CAC=25 dB according to ASTM E 1414 and evaluation according to ASTM E 413.
Sound Privacy: AC(1.5)=180 according to ASTM E 1111 and E 1110.
Product Focus Ds
o.d.s mm 60 75 200 400
Class B A A
αw 0,80 0,90 0,90
NRC 0,90 - - 0,80
SAA 0,90 - - 0,82
Technical properties
Accessibility: The tiles in size 600x600 and 1200x600 are easliy demountable. The tiles in size 1200x1200 and XL sizes are demountable. Minimum demounting depth according to installation diagrams.
Cleanability: Daily dusting and vacuum cleaning. Weekly wet wiping.
Visual appearance: White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection). Retro reflection coefficient 63 mcd/(m²lx). Gloss < 1.
Influence of climate: The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate: Certified by the Indoor Climate Labelling, emission class M1 for building materials and recommended by the Swedish Asthma and Allergy Association.
Environmental influence: Glass wool core utilizing 3RD Technology. Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety: The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003.
Country Standard Class
Europe EN 13501-1 A2-s1,d0
Mechanical properties: See table about Max live load and Min load bearing capacity and Functional demands, Mechanical properties at www.ecophon.com.
Max live load (N) Min load bearing capacity (N)
M206, 600x600 50 160
M206, 1200x600 50 160
M206, 1600x600 50 160
M206, 1800x600 50 160
M206, 2000x600 50 160
M206, 2400x600 50 160
M207, 1200x1200 50 160
M208, 600x600 50 160
M208, 1200x600 50 160
M208, 1600x600 50 160
M208, 1800x600 50 160
M208, 2000x600 50 160
M208, 2400x600 50 160
M238, 1600x600 40 -
M238, 1800x600 20 -
M238, 2000x600 10 -
M238, 2400x600 0 -
Installation: Installed according to installation diagrams, installation guides and drawing aid. For information regarding minimum overall depth of system see quantity specification. The systems are not recommended for small rooms (approximately 2x2 m2). Ceilings with a large amount of integrations require careful planning, design and installation.