System range
Size, mm
XL
XL
XL
XL
600x600
1200x600
1200x1200
1600x600
1800x600
2000x600
2400x600
T24
•
•
•
•
•
•
•
Thickness
20
20
20
20
20
20
20
Inst. Diagr.
M206
M208
M206
M208
M207
M206
M208
M238
M206
M208
M238
M206
M208
M238
M206
M208
M238
System and product description
For applications where a suspended ceiling with a concealed grid is required, but individual tiles must be easily demountable. Ecophon Focus Ds has a concealed grid and symmetrical edge design, allowing easier assembly, integration of light fittings and ventilation. The ceiling has an even appearance, with the bevelled edges forming a discreet groove between the tiles. The tiles are easily demountable.
The systems consist of Ecophon Focus Ds tiles and Ecophon Connect grid systems, with an approximate weight of 3-4 kg/m². The tiles are manufactured from high density glass wool utilizing the 3RD Technology. The visible surface has an Akutex™ FT coating and the back of the tile is covered with glass tissue. The edges are painted. For best performance and system quality, use Ecophon Connect grid and accessories. The grid is manufactured from galvanized steel. The system is patented.
M206
M207
M208
M238
M206
VIEW 3D
Download installation guide
IG206
-Focus Ds
(2.66 MB)
Accessibility
-guide Focus Ds
(109.03 kB)
Drawing Aid
Transitions
Installations
Fixings
Search
See Quantity specification
Secured Main runner at wall with Connect Wall bracket
Connection between profiles with space bar winch
Cross tee used for keeping tiles in position
Quantity specification (excl. wastage)
Installation diagram (M206) for Ecophon Focus Ds 600x600, 1200x600 mm and Ecophon Focus Ds XL. Suspended installation
Size, mm
600x600
1200x600
1600x600
1800x600
2000x600
2400x600
1 Focus Ds
2,8/m²
1,4/m²
1,05/m²
0,95/m²
0,85/m²
0,7/m²
2 Connect T24 Main runner HD, installed at 600 mm centres
1,7m/m²
1,7m/m²
1,7m/m²
1,7m/m²
1,7m/m²
1,7m/m²
3 Connect Wall bracket for T-profiles
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
4 Connect Space bar, installed at 1500 mm centres (max. distance from wall 300 mm)
0,7m/m²
0,7m/m²
0,7m/m²
0,7m/m²
0,7m/m²
0,7m/m²
5 Connect Wall bracket, L=700 mm, for Space bar
1 for every row of Space bar
1 for every row of Space bar
1 for every row of Space bar
1 for every row of Space bar
1 for every row of Space bar
1 for every row of Space bar
6 Connect T24 Cross tee, L=600 mm
2per row of Main runner
2per row of Main runner
2per row of Main runner
2per row of Main runner
2per row of Main runner
2per row of Main runner
7 Connect Space bar winch, installed one per joint Main runner/Space bar
1,4/m²
1,4/m²
1,4/m²
1,4/m²
1,4/m²
1,4/m²
8 Connect Adjustable hanger, installed at 1200 mm centres (max. distance from wall 600 mm)
0,7/m²
0,7/m²
0,7/m²
0,7/m²
0,7/m²
0,7/m²
9 Connect Hanger clip
0,7/m²
0,7/m²
0,7/m²
0,7/m²
0,7/m²
0,7/m²
10 Connect Support clip Dg20
1pc/300-400 mm on every cut perimeter tile with only 1 supporting edge
1pc/300-400 mm on every cut perimeter tile with only 1 supporting edge
1pc/300-400 mm on every cut perimeter tile with only 1 supporting edge
1pc/300-400 mm on every cut perimeter tile with only 1 supporting edge
1pc/300-400 mm on every cut perimeter tile with only 1 supporting edge
1pc/300-400 mm on every cut perimeter tile with only 1 supporting edge
11 Connect Angle trim 15/22, fixed at 300 mm centres
as required
as required
as required
as required
as required
as required
12 Connect Perimeter tile clip
1 /300-400mm on any cut edge
1 /300-400mm on any cut edge
1 /300-400mm on any cut edge
1 /300-400mm on any cut edge
1 /300-400mm on any cut edge
1 /300-400mm on any cut edge
Δ Min. overall depth of system: 105 mm
-
-
-
-
-
-
δ Min. demounting depth: 30 mm
-
-
-
-
-
-
M207
VIEW 3D
Download installation guide
IG207
-Focus Ds
(2.04 MB)
Drawing Aid
Transitions
Installations
Fixings
Search
See Quantity specification
Secured Main runner at wall with Connect Wall bracket
Connection between profiles with space bar winch
Connection between Main runner and Edge stiffener
Quantity specification (excl. wastage)
Installation diagram (M207) for Ecophon Focus Ds 1200x1200 mm
Size, mm
1200x1200
1 Focus Ds
0,7/m²
2 Connect T24 Main runner HD, installed at 1200 mm centres (max. distance from wall 600 mm, can be extended up to 1200 mm if no live load between Main runner and wall).
0,9m/m²
3 Connect Wall bracket for T-profiles
1for every row of suspended Main runner HD
4 Connect Space bar, installed at 1500 mm centres (max. distance from wall 300 mm)
0,7m/m²
5 Connect Wall bracket, L=700 mm, for Space bar
1 for every row of Space bar
6 Connect Edge stiffener
1,4/m²
7 Connect Stop clip
2for every row of Main runner
8 Connect Space bar winch, installed one per joint Main runner/Space bar
0,55/m²
9 Connect Adjustable hanger, installed at 1200 mm centres (max. distance from wall 600 mm)
0,7/m²
10 Connect Hanger clip
0,7/m²
11 Connect Angle trim 15/22, fixed at 300 mm centres
as required
12 Connect Perimeter tile clip
1 /300-400mm on any cut edge
Δ Min. overall depth of system: 105 mm
-
δ Min. demounting depth: 50 mm
-
M208
VIEW 3D
Download installation guide
IG208
-Focus Ds
(1.43 MB)
Drawing Aid
Transitions
Installations
Fixings
Search
See Quantity specification
Secured Main runner at wall with Connect Wall bracket
Suspension with direct fix bracket
Cross tee used for keeping tiles in position
Quantity specification (excl. wastage)
Installation diagram (M208) for Ecophon Focus Ds, direct installation
Size, mm
600x600
1200x600
1600x600
1800x600
2000x600
2400x600
1 Focus Ds
2,8/m²
1,4/m²
1,05/m²
0,95/m²
0,85/m²
0,7/m²
2 Connect T24 Main runner HD, installed at 600 mm centres
1,7m/m²
1,7m/m²
1,7m/m²
1,7m/m²
1,7m/m²
1,7m/m²
3 Connect Wall bracket for T-profiles
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
1for every row of suspended Main runner HD
4 Connect T24 Cross Tee, L=600
2/row of Main runner
2/row of Main runner
2/row of Main runner
2/row of Main runner
2/row of Main runner
2/row of Main runner
5 Connect Direct bracket, installed at 1500 mm centres
1,1/m²
1,1/m²
1,1/m²
1,1/m²
1,1/m²
1,1/m²
6 Connect Support clip Dg20
1 /300-400mm on any cut edge
1 /300-400mm on any cut edge
1 /300-400mm on any cut edge
1 /300-400mm on any cut edge
1 /300-400mm on any cut edge
1 /300-400mm on any cut edge
7 Connect Angle trim 15/22, fixed at 300 mm centres
as required
as required
as required
as required
as required
as required
8 Connect Perimeter tile clip can be used if sufficent space is available.
1pc/300-400 mm on every cut perimeter tile with only 1 supporting edge
1pc/300-400 mm on every cut perimeter tile with only 1 supporting edge
1pc/300-400 mm on every cut perimeter tile with only 1 supporting edge
1pc/300-400 mm on every cut perimeter tile with only 1 supporting edge
1pc/300-400 mm on every cut perimeter tile with only 1 supporting edge
1pc/300-400 mm on every cut perimeter tile with only 1 supporting edge
Δ Min. overall depth of system: 65 mm
-
-
-
-
-
-
δ Min. demounting depth: 30 mm
-
-
-
-
-
-
M238
VIEW 3D
Download installation guide
IG238
-Focus Ds Corridor
(843.72 kB)
Drawing Aid
Transitions
Installations
Fixings
Search
See Quantity specification
Tile and Connect Cover trim Ds
Corridor profile positioned by Modular wall trim
Quantity specification (excl. wastage)
Installation diagram (M238) for Ecophon Focus Ds XL in corridors
Size, mm
1600x600
1800x600
2000x600
2400x600
1 Focus Ds XL
1,05/m²
0,95/m²
0,85/m²
0,7/m²
2 Connect Modular Wall trim
as required
as required
as required
as required
3 Connect T24 Corridor profile
1,05/m²
0,95/m²
0,85/m²
0,7/m²
4 Connect Cover trim Ds
2/tile plus end tiles
2/tile plus end tiles
2/tile plus end tiles
2/tile plus end tiles
5 Connect Support clip Dg 20
1pc/300-400 mm on every cut perimeter tile with only 1 supporting edge
1pc/300-400 mm on every cut perimeter tile with only 1 supporting edge
1pc/300-400 mm on every cut perimeter tile with only 1 supporting edge
1pc/300-400 mm on every cut perimeter tile with only 1 supporting edge
Δ Min. overall depth of system: 55 mm
-
-
-
-
δ Min. demounting depth: 30 mm
-
-
-
-
Acoustics
Acoustic:
α
p
Practical sound absorption coefficient
Frequency Hz
—
Ecophon Focus Ds 200 mm o.d.s.
····
Ecophon Focus Ds 60 mm o.d.s.
o.d.s = overall depth of system
Sound Absorption:
Test results according to EN ISO 354.
Classification according to EN ISO 11654, and the single value ratings for NRC and SAA according to ASTM C 423.
Sound Insulation:
Dn,f,w=24 dB according to ISO 140-9 and evaluation according to EN ISO 717-1. CAC=25 dB according to ASTM E 1414 and evaluation according to ASTM E 413.
Sound Privacy:
AC(1.5)=180 according to ASTM E 1111 and E 1110.
Product
Focus Ds
o.d.s mm
60
75
200
400
Class
B
A
A
αw
0,80
0,90
0,90
NRC
0,90
-
-
0,80
SAA
0,90
-
-
0,82
Technical properties
Accessibility:
The tiles in size 600x600 and 1200x600 are easliy demountable. The tiles in size 1200x1200 and XL sizes are demountable. Minimum demounting depth according to installation diagrams.
Cleanability:
Daily dusting and vacuum cleaning. Weekly wet wiping.
Visual appearance:
White Frost, nearest NCS colour sample S 0500-N, 85% light reflectance (of which more than 99% is diffuse reflection). Retro reflection coefficient 63 mcd/(m²lx). Gloss < 1.
Influence of climate:
The tiles withstand a permanent ambient RH up to 95% at 30°C without sagging, warping or delaminating (ISO 4611).
Indoor Climate:
Certified by the Indoor Climate Labelling, emission class M1 for building materials and recommended by the Swedish Asthma and Allergy Association.
Environmental influence:
Glass wool core utilizing 3RD Technology. Granted the Nordic Swan eco-label. Fully recyclable.
Fire safety:
The glass wool core of the tiles is tested and classified as non-combustible according to EN ISO 1182. The systems are classified as fire protective covering according to NT FIRE 003.
Country
Standard
Class
Europe
EN 13501-1
A2-s1,d0
Mechanical properties:
See table about Max live load and Min load bearing capacity and Functional demands, Mechanical properties at www.ecophon.com.
Max live load (N)
Min load bearing capacity (N)
M206
, 600x600
50
160
M206
, 1200x600
50
160
M206
, 1600x600
50
160
M206
, 1800x600
50
160
M206
, 2000x600
50
160
M206
, 2400x600
50
160
M207
, 1200x1200
50
160
M208
, 600x600
50
160
M208
, 1200x600
50
160
M208
, 1600x600
50
160
M208
, 1800x600
50
160
M208
, 2000x600
50
160
M208
, 2400x600
50
160
M238
, 1600x600
40
-
M238
, 1800x600
20
-
M238
, 2000x600
10
-
M238
, 2400x600
0
-
Installation:
Installed according to installation diagrams, installation guides and drawing aid. For information regarding minimum overall depth of system see quantity specification. The systems are not recommended for small rooms (approximately 2x2 m2). Ceilings with a large amount of integrations require careful planning, design and installation.
Contact us
We can help with technical solutions and answers to your questions about our products or room acoustics.
Read more
Connect Bridging
Connect Bridging is a simple solution for integration of lighting products, signs, smoke detectors etc. The weight of the installation will be transferred to the grid, and there will be no load on the tile.
Read more
3D CAD
A new feature turns watching installation diagrams into a 3D experience! Add another dimension to watching our installation diagrams. With our latest innovation we let you twist and turn and view close-ups directly on your computer.
Read more
It's new, it's fresh - it's the new Acoustics
The new Acoustics features applied room acoustics for Office, Education and Healthcare premises. Here you can explore the individual segments, and by using the room selector you can read up on the specific needs and acoustic solutions for that particular room.
Read more
Copyright © 2002-2013 Ecophon Group. All rights reserved.
Trademarks
Cookies
Disclaimer
Tell a friend
Close
Your friends name:
*
Your friends email:
*
Your name:
*
Your e-mail:
*
Your message:
Transitions
Installation
Fixing
Search
Category
Subcategory
Detail list
Previous image
Next image
Type
Name
Description
Product
Sketch
Result
Previous image
Next image
Close